1. Statutory Regulations: SOLAS Chapter II-2 Reg 4.5 & ISGOTT 6th Edition Mandates
Crude oil and chemical tankers transport volatile hydrocarbon cargoes capable of generating explosive vapor-air atmospheres. Under SOLAS Chapter II-2 Regulation 4.5.5 and the International Safety Guide for Oil Tankers and Terminals (ISGOTT 6th Edition), all crude oil tankers of 20,000 DWT and upwards, and chemical tankers carrying low-flashpoint products, must maintain an inert atmosphere inside cargo tanks at all times.
2. Inert Gas Systems (IGS): Oxygen Content Analyzers (≤ 5% O2) & Main Deck Seals
The Inert gas system bridge telemetry network continuously monitors the inert gas quality generated by flue gas scrubbers or nitrogen generators:
- Zirconia Oxygen Analyzers: Continuously measures oxygen percentage before inert gas enters cargo tanks. Under SOLAS, oxygen content must never exceed 5% by volume during delivery, and tanks must maintain positive pressure (≥ 200 mmWG) to prevent air ingress.
- Deck Water Seal Telemetry: Monitors water seal levels preventing hydrocarbon vapors from flowing backward into machinery spaces.
3. Crude Oil Washing (COW): MARPOL Annex I Shadow Diagrams & Pressure Transducers
Under MARPOL Annex I Regulation 33, tankers discharge crude oil residues using automated Crude Oil Washing (COW) machines. High-pressure crude washing jets dissolve wax and asphaltic sediments. Telemetry monitors wash pump pressure, nozzle rotation speeds, and cargo tank inert gas oxygen levels (≤ 8% O2 limit during washing).
4. Vapor Emission Control (VECS): High-Velocity P/V Valves & Vapor Pressure Sensors
During high-rate tanker loading, displaced hydrocarbon vapors are collected via Vapor Emission Control Systems (VECS) and piped back to shore terminals. Redundant pressure transmitters and high-velocity Pressure/Vacuum (P/V) valves ensure tank pressure does not exceed structural design limits.
5. Pump Room & Bilge Safety: Hydrocarbon Gas Detectors & Emergency Bilge Alarms
Tanker cargo pump rooms represent high-risk enclosed spaces. Continuous hydrocarbon infrared gas detection arrays (sampling at bottom, middle, and upper levels) sound alarms if gas exceeds 10% LEL, while bilge float switches trip remote emergency dewatering pumps.
6. Environmental Telemetry: Sludge Tank Gauging & Oily Water Separator (OWS) 15-PPM Monitors
Under MARPOL Annex I, engine room bilge discharge requires certified 15-PPM Oily Water Separator Bilge Alarms with automated electronic logbook recording, preventing illegal oily water discharge into marine sanctuaries.
Turnkey Tanker Safety, IGS & Gas Detection Telemetry
Seanav Marine supplies, overhauls, and certifies tanker Inert Gas Systems, oxygen analyzers, pump room gas detection arrays, and 15-PPM bilge monitors across all Indian tanker berths and refineries.
7. Technical FAQs: Tanker Safety & Inert Gas Systems
Q1: What is the maximum oxygen percentage allowed for inert gas delivered to cargo tanks?
Under SOLAS Chapter II-2, inert gas supplied to cargo tanks must have an oxygen content of not more than 5% by volume. Inside the cargo tanks, the oxygen content must be maintained at not more than 8% by volume at all times to prevent explosion.
Q2: What is the function of the deck water seal in an Inert Gas System?
The deck water seal is a statutory safety barrier installed on the main deck. It acts as a non-return water trap that allows inert gas to flow forward into cargo tanks while completely preventing dangerous hydrocarbon gases from traveling back toward engine room machinery spaces.
Q3: What triggers an alarm on a 15-PPM bilge separator monitor?
Under MARPOL Annex I, an optical scatter sensor monitors treated bilge water. If oil content exceeds 15 parts per million (PPM), the system sounds bridge alarms and automatically activates a 3-way solenoid valve diverting effluent back into the bilge holding tank.