Under MARPOL Annex I (Regulation 14) and mandatory IMO Resolution MEPC.107(49), all commercial vessels of 400 GT and upwards must operate an approved Oily Water Separator (OWS) fitted with an Oil Content Meter (OCM / 15 PPM Bilge Alarm). The system must continuously monitor engine room bilge effluent, maintain tamper-proof electronic data logging, and automatically actuate a 3-way valve to divert discharge back to bilge holding tanks whenever oil content exceeds 15 parts per million.
Engineering Overview & Table of Contents
- 1. Regulatory Framework: MARPOL Annex I & MEPC.107(49) Requirements
- 2. 15 PPM Bilge Alarm Calibration, Optical Cell Cleaning & Descaling
- 3. 3-Way Overboard Diversion Valve Servicing & Fail-Safe Actuation
- 4. OWS Mechanical Overhaul: Coalescer Filters, Oil Skimmers & Heating Coils
- 5. Oil Discharge Monitoring Equipment (ODME) Interfacing for Tankers
- 6. Class Survey Calibration & Port Attendance Across India
1. Regulatory Framework: MARPOL Annex I & MEPC.107(49) Requirements
MARPOL violations concerning oily bilge discharges carry severe criminal penalties, Port State Control (PSC) detentions, and substantial environmental fines. IMO Resolution MEPC.107(49) mandates that 15 PPM alarm units must be tamper-proof, record date, time, alarm status, and operating status, and withstand heavy oil emulsions. Seanav provides certified 15 PPM Bilge Alarm Electronics Service, Oily Water Separator Automation Servicing, and annual calibration across Deckma Hamburg (OMD-21 / OMD-24 / OMD-2005 / OMD-2008), Rivertrace (Smartcell 15ppm), Fellowship, and Georim systems.
2. 15 PPM Bilge Alarm Calibration, Optical Cell Cleaning & Descaling
The measuring cell utilizes multiple optical scattered-light infrared sensors to detect oil droplets in the sample stream:
15 PPM Alarm Calibration & Servicing Sequence:
- Measuring Cell Descaling: Flushing optical glass tube with specialized mild cleaning solvents, wiping optical windows, and renewing wiper seals.
- Zero Calibration: Supplying clean fresh water to verify zero-point optical reference; ensuring baseline reading displays 0.0 ± 0.5 PPM.
- Span Calibration with Certified Turbidity Fluid: Testing optical response against factory calibration fluid (traceable to MEPC.107(49) test fluid standards); confirming exact PPM alarm trip at 15.0 PPM.
- Tamper-Proof Data Logger Audit: Verifying non-volatile memory retains at least 18 months of timestamped discharge logs; validating anti-tampering sensor seals.
3. 3-Way Overboard Diversion Valve Servicing & Fail-Safe Actuation
The pneumatic or electric 3-way valve determines whether effluent discharges safely overboard or recycles back to the bilge holding tank:
- Fail-Safe Overboard Closure: Verifying that upon loss of electrical power, pneumatic air failure, or when reading exceeds 15 PPM, the valve instantly springs back to the bilge tank recycling position (closing time < 2 seconds).
- Pneumatic Actuator Overhaul: Replacing piston seals, cleaning solenoid directional valves, and renewing air filter regulators.
- Auxiliary Contact Feedback: Confirming valve position limit switches feed real-time overboard status into the 15 PPM unit’s data logger and engine room alarm monitoring system.
4. OWS Mechanical Overhaul: Coalescer Filters, Oil Skimmers & Heating Coils
A properly calibrated 15 PPM monitor requires an efficient mechanical separator. Seanav overhauls the entire OWS skid:
| OWS Stage | Operational Condition | Seanav Overhaul Scope |
|---|---|---|
| Stage 1: Gravitational / Coalescer Plate Pack | Free oil separation & rising to dome | High-pressure washing oleophilic corrugated plates; checking steam heating coils and automatic oil discharge probe electrodes. |
| Stage 2: Emulsion Breaking / Absorption Filters | Trapping emulsified droplets < 20 μm | Replacing spent granular activated carbon, ceramic coalescer cartridges, or synthetic polymer filter elements. |
| Progressive Cavity Feed Pump | Low-shear positive displacement flow | Overhauling eccentric screw pumps (Moyno / Seepex / Mono); replacing rubber stators and chrome-plated rotors to eliminate fluid shear emulsification. |
5. Oil Discharge Monitoring Equipment (ODME) Interfacing for Tankers
For oil tankers operating under MARPOL Annex I Regulation 31, Seanav provides Oil Discharge Monitoring Equipment (ODME) Electronics Service across Martec, Rivertrace, and VAF systems. Our engineers calibrate optical measuring cells, overhaul dirty ballast water sample pumps, verify speed log and flow meter rate inputs, and test automatic discharge overboard shutoff valves.
6. Class Survey Calibration & Port Attendance Across India
Seanav service engineers board vessels with calibrated testing rigs and factory-sealed replacement measuring cells across Kandla, Mundra, Sikka, Mumbai, JNPT, Cochin, Chennai, Paradip, and Visakhapatnam. We issue official MEPC.107(49) Calibration Certificates recognized by all IACS classification societies.
Schedule 15 PPM Bilge Alarm Calibration or OWS Servicing